Combi Basic
- Funções principais
- Technical features
- Expansion Boards
- Warning Grounding System
-
Protocols Management for call-center (ex. Ademco Contact ID, P100).
-
Simplified wiring system for speaker modules (Speakerlift) 2 wires.
-
GSM line input with GSM300 device (optional).
-
Programming by telephone keypad; locally and remotely.
-
Programming via graphic display DISP903.
-
Programming via Vegacom APP (only if there is GSM300).
-
Programming via Managerlift (Vega Cloud).
-
Memory capacity up to 10 phone numbers.
-
32 customizable messages divided into 4 languages.
-
Inductive loop facility for the hard-of-hearing.
-
4 types of inputs: alarm input, alarm filter input, technical alarm input and reset alarm input.
-
Sent and acknowledged alarm signals.
- Input power supply: from 11V to 14V DC.
- Output power supply: 12V DC 500 mA.
- Inputs: 4x opto islator 5-50V 50mA.
- Outputs: 2 open collectors.
- Size: 111x92x50 mm
Cb Line: Analog line interface.
Main Features:
- PSTN analog line input.
Cb Rele: Relay board.
Main Features:
- 2 Relay outputs for piloting locally and remotely.
Cb Bat: UPS board.
Main Features:
- Allows for supply Auto-Dialer with voltage between 9 and 24 V AC/ DC.
- Power supply filter against interferences.
- 12 V rechargeable battery input.
- Battery charger function.
- Efficiency battery monitoring. Technical alarms management: low and /or inefficient battery, no electricity.
WARNING GROUNDING SYSTEM
In case of installation of the device on a metal fixture, it is strongly recommended to connect the fixture to the grounding system, to avoid malfunction or damage to the electronic device installation.